Heat Load - Highlight Series Inserts with Fluorescent Lighting 1800x700
Highlight Series M/T (Non Heated Glass) |
||||||||
| 1800mm H x 700mm Double Glazed Non Heated Glass Medium Temperature |
1 Door | 2 Door | 3 Door | 4 Door | 5 Door | 6 Door | 7 Door | 8 Door |
|---|---|---|---|---|---|---|---|---|
| Store Conditions 25˚C & 60% RH | 206 | 343 | 480 | 617 | 755 | 892 | 1029 | 1166 |
| NON-HEATED GLASS DOORS AIR CONDITIONED APPLICATIONS 25˚C & 60% RH ONLY | ||||||||
Highlight Series M/T 'Mullionless' (Non Heated Glass) |
||||||||
| 1800mm H x 700mm Double Glazed Non Heated Glass Medium Temperature |
1 Door | 2 Door | 3 Door | 4 Door | 5 Door | 6 Door | 7 Door | 8 Door |
|---|---|---|---|---|---|---|---|---|
| Store Conditions 25˚C & 60% RH | 224 | 320 | 417 | 536 | 622 | 747 | 821 | 918 |
| NON-HEATED GLASS DOORS AIR CONDITIONED APPLICATIONS 25˚C & 60% RH ONLY | ||||||||
Highlight Series L/T (Non Heated Glass) |
||||||||
| 1800mm H x 700mm Double Glazed Non Heated Glass Medium Temperature |
1 Door | 2 Door | 3 Door | 4 Door | 5 Door | 6 Door | 7 Door | 8 Door |
|---|---|---|---|---|---|---|---|---|
| Store Conditions 25˚C & 60% RH | 256 | 493 | 732 | 967 | 1210 | 1449 | 1688 | 1927 |
| NON-HEATED GLASS DOORS AIR CONDITIONED APPLICATIONS 25˚C & 60% RH ONLY | ||||||||
Tropical Highlight Series M/T (Heated Glass) |
||||||||
| 1800mm H x 700mm Double Glazed Heated Glass Medium Temperature |
1 Door | 2 Door | 3 Door | 4 Door | 5 Door | 6 Door | 7 Door | 8 Door |
|---|---|---|---|---|---|---|---|---|
| Store Conditions 25˚C & 60% RH | 237 | 405 | 574 | 743 | 911 | 1079 | 1247 | 1416 |
| Store Conditions 30˚C & 70% RH | 255 | 440 | \627 | 813 | 999 | 1185 | 1371 | 1557 |
| Store Conditions 35˚C & 70% RH | 275 | 482 | 688 | 896 | 1102 | 1309 | 1515 | 1722 |
| Store Conditions 40˚C & 70% RH | 299 | 529 | 760 | 991 | 1221 | 1452 | 1682 | 1913 |
Tropical Highlight Series M/T 'Mullionless' (Heated Glass) |
||||||||
| 1800mm H x 700mm Double Glazed Heated Glass Medium Temperature |
1 Door | 2 Door | 3 Door | 4 Door | 5 Door | 6 Door | 7 Door | 8 Door |
|---|---|---|---|---|---|---|---|---|
| Store Conditions 25˚C & 60% RH | 377 | 426 | 576 | 749 | 888 | 1066 | 1193 | 1343 |
| Store Conditions 30˚C & 70% RH | 297 | 466 | 637 | 829 | 989 | 1168 | 1333 | 1504 |
| Store Conditions 35˚C & 70% RH | 318 | 508 | 698 | 912 | 1092 | 1210 | 1478 | 1669 |
| Store Conditions 40˚C & 70% RH | 342 | 555 | 770 | 1007 | 1211 | 1453 | 1644 | 1859 |
Tropical Highlight Series Low Temperature (Heated Glass) |
||||||||
| 1800mm H x 700mm Double Glazed Heated Glass Medium Temperature |
1 Door | 2 Door | 3 Door | 4 Door | 5 Door | 6 Door | 7 Door | 8 Door |
|---|---|---|---|---|---|---|---|---|
| Store Conditions 25˚C & 60% RH | 303 | 586 | 873 | 1154 | 1444 | 1729 | 2015 | 2301 |
| Store Conditions 30˚C & 70% RH | 328 | 636 | 948 | 1254 | 1568 | 1879 | 2189 | 2501 |
| Store Conditions 35˚C & 70% RH | 358 | 696 | 1037 | 1374 | 1718 | 2059 | 2399 | 2741 |
| Store Conditions 40˚C & 70% RH | 393 | 766 | 1143 | 1514 | 1893 | 2269 | 2644 | 3021 |