Heat Load - Highlight Series L.E.D Lighting 1800x750
Highlight Series M/T (Non Heated Glass) |
||||||||
| 1800mm H x 750mm Double Glazed Non Heated Glass Medium Temperature |
1 Door | 2 Door | 3 Door | 4 Door | 5 Door | 6 Door | 7 Door | 8 Door |
|---|---|---|---|---|---|---|---|---|
| Store Conditions 25˚C & 60% RH | 159 | 287 | 415 | 543 | 672 | 800 | 928 | 1057 |
| NON-HEATED GLASS DOORS AIR CONDITIONED APPLICATIONS 25˚C & 60% RH ONLY | ||||||||
Highlight Series M/T 'Mullionless' (Non Heated Glass) |
||||||||
| 1800mm H x 750mm Double Glazed Non Heated Glass Medium Temperature |
1 Door | 2 Door | 3 Door | 4 Door | 5 Door | 6 Door | 7 Door | 8 Door |
|---|---|---|---|---|---|---|---|---|
| Store Conditions 25˚C & 60% RH | 139 | 247 | 355 | 464 | 572 | 681 | 789 | 897 |
| NON-HEATED GLASS DOORS AIR CONDITIONED APPLICATIONS 25˚C & 60% RH ONLY | ||||||||
Highlight Series L/T (Non Heated Glass) |
||||||||
| 1800mm H x 750mm Double Glazed Non Heated Glass Medium Temperature |
1 Door | 2 Door | 3 Door | 4 Door | 5 Door | 6 Door | 7 Door | 8 Door |
|---|---|---|---|---|---|---|---|---|
| Store Conditions 25˚C & 60% RH | 230 | 414 | 599 | 784 | 968 | 1152 | 1337 | 1521 |
| NON-HEATED GLASS DOORS AIR CONDITIONED APPLICATIONS 25˚C & 60% RH ONLY | ||||||||
Tropical Highlight Series M/T (Heated Glass) |
||||||||
| 1800mm H x 750mm Double Glazed Heated Glass Medium Temperature |
1 Door | 2 Door | 3 Door | 4 Door | 5 Door | 6 Door | 7 Door | 8 Door |
|---|---|---|---|---|---|---|---|---|
| Store Conditions 25˚C & 60% RH | 192 | 355 | 516 | 678 | 840 | 1002 | 1163 | 1325 |
| Store Conditions 30˚C & 70% RH | 211 | 391 | 570 | 751 | 931 | 1111 | 1291 | 1471 |
| Store Conditions 35˚C & 70% RH | 231 | 433 | 633 | 834 | 1036 | 1237 | 1437 | 1638 |
| Store Conditions 40˚C & 70% RH | 256 | 481 | 705 | 931 | 1156 | 1384 | 1606 | 1831 |
Tropical Highlight Series M/T 'Mullionless' (Heated Glass) |
||||||||
| 1800mm H x 750mm Double Glazed Heated Glass Medium Temperature |
1 Door | 2 Door | 3 Door | 4 Door | 5 Door | 6 Door | 7 Door | 8 Door |
|---|---|---|---|---|---|---|---|---|
| Store Conditions 25˚C & 60% RH | 184 | 360 | 523 | 688 | 852 | 1017 | 1181 | 1345 |
| Store Conditions 30˚C & 70% RH | 215 | 401 | 586 | 771 | 956 | 1141 | 1326 | 1511 |
| Store Conditions 35˚C & 70% RH | 236 | 443 | 648 | 854 | 1060 | 1267 | 1472 | 1678 |
| Store Conditions 40˚C & 70% RH | 260 | 491 | 721 | 951 | 1181 | 1411 | 1641 | 1871 |
Tropical Highlight Series Low Temperature (Heated Glass) |
||||||||
| 1800mm H x 750mm Double Glazed Heated Glass Medium Temperature |
1 Door | 2 Door | 3 Door | 4 Door | 5 Door | 6 Door | 7 Door | 8 Door |
|---|---|---|---|---|---|---|---|---|
| Store Conditions 25˚C & 60% RH | 280 | 515 | 750 | 985 | 1220 | 1455 | 1689 | 1924 |
| Store Conditions 30˚C & 70% RH | 306 | 566 | 826 | 1088 | 1348 | 1608 | 1869 | 2129 |
| Store Conditions 35˚C & 70% RH | 336 | 626 | 917 | 1208 | 1499 | 1789 | 2080 | 2370 |
| Store Conditions 40˚C & 70% RH | 371 | 697 | 1023 | 1350 | 1675 | 2001 | 2327 | 2652 |