Heat Load - Standard Series Fluorescent Lighting 1800x500

Download the PDF

Standard Series M/T (Non Heated Glass)

1800mm H x 500mm Double Glazed Non Heated
Glass Medium Temperature
1 Door 2 Door 3 Door 4 Door 5 Door 6 Door 7 Door 8 Door
Store Conditions 25˚C & 60% RH 306 463 620 777 934 1091 1248 1405
NON-HEATED GLASS DOORS AIR CONDITIONED APPLICATIONS 25˚C & 60% RH ONLY

Standard Series M/T 'Mullionless' (Non Heated Glass)

1800mm H x 500mm Double Glazed Non Heated
Glass Medium Temperature
1 Door 2 Door 3 Door 4 Door 5 Door 6 Door 7 Door 8 Door
Store Conditions 25˚C & 60% RH 306 435 562 662 787 915 998 1142
NON-HEATED GLASS DOORS AIR CONDITIONED APPLICATIONS 25˚C & 60% RH ONLY

Standard Series M/T (Heated Glass)

1800mm H x 500mm Double Glazed Heated Glass
Medium Temperature
1 Door 2 Door 3 Door 4 Door 5 Door 6 Door 7 Door 8 Door
Store Conditions 25˚C & 60% RH 349 550 750 950 1149 1350 1550 1750
Store Conditions 30˚C & 70% RH 379 609 839 1068 1297 1527 1757 1986
Store Conditions 35˚C & 70% RH 401 653 904 1156 1406 1658 1910 2161
Store Conditions 40˚C & 70% RH 427 706 984 1262 1539 1818 2096 2374

Standard Series M/T 'Mullionless' (Heated Glass)

1800mm H x 500mm Double Glazed Heated Glass
Medium Temperature
1 Door 2 Door 3 Door 4 Door 5 Door 6 Door 7 Door 8 Door
Store Conditions 25˚C & 60% RH 366 554 740 899 1083 1271 1413 1617
Store Conditions 30˚C & 70% RH 397 617 834 1024 1240 1459 1632 1867
Store Conditions 35˚C & 70% RH 419 660 900 1112 1349 1590 1785 2042
Store Conditions 40˚C & 70% RH 446 714 980 1218 1483 1750 1972 2255

Standard Series Low Temperature (Heated Glass)

1800mm H x 500mm Double Glazed Heated Glass
Medium Temperature
1 Door 2 Door 3 Door 4 Door 5 Door 6 Door 7 Door 8 Door
Store Conditions 25˚C & 60% RH 562 950 1338 1727 2115 2504 2892 3280
Store Conditions 30˚C & 70% RH 609 1044 1479 1914 2349 2785 3220 3655
Store Conditions 35˚C & 70% RH 642 1109 1578 2046 2514 2982 3451 3918
Store Conditions 40˚C & 70% RH 681 1187 1695 2202 2709 3216 3723 4230