Heat Load - Standard Series Fluorescent Lighting 800x500
Standard Series M/T (Non Heated Glass) |
||||||||
| 800mm H x 500mm Double Glazed Non Heated Glass Medium Temperature |
1 Door | 2 Door | 3 Door | 4 Door | 5 Door | 6 Door | 7 Door | 8 Door |
|---|---|---|---|---|---|---|---|---|
| Store Conditions 25˚C & 60% RH | 147 | 233 | 319 | 405 | 490 | 576 | 662 | 748 |
| NON-HEATED GLASS DOORS AIR CONDITIONED APPLICATIONS 25˚C & 60% RH ONLY | ||||||||
Standard Series M/T 'Mullionless' (Non Heated Glass) |
||||||||
| 800mm H x 500mm Double Glazed Non Heated Glass Medium Temperature |
1 Door | 2 Door | 3 Door | 4 Door | 5 Door | 6 Door | 7 Door | 8 Door |
|---|---|---|---|---|---|---|---|---|
| Store Conditions 25˚C & 60% RH | 147 | 245 | 341 | 410 | 505 | 602 | 654 | 767 |
| NON-HEATED GLASS DOORS AIR CONDITIONED APPLICATIONS 25˚C & 60% RH ONLY | ||||||||
Standard Series M/T (Heated Glass) |
||||||||
| 800mm H x 500mm Double Glazed Heated Glass Medium Temperature |
1 Door | 2 Door | 3 Door | 4 Door | 5 Door | 6 Door | 7 Door | 8 Door |
|---|---|---|---|---|---|---|---|---|
| Store Conditions 25˚C & 60% RH | 165 | 270 | 374 | 479 | 582 | 688 | 792 | 896 |
| Store Conditions 30˚C & 70% RH | 182 | 305 | 427 | 549 | 670 | 793 | 915 | 1037 |
| Store Conditions 35˚C & 70% RH | 196 | 332 | 468 | 603 | 738 | 874 | 1010 | 1145 |
| Store Conditions 40˚C & 70% RH | 213 | 366 | 518 | 671 | 822 | 976 | 1128 | 1280 |
Standard Series M/T 'Mullionless' (Heated Glass) |
||||||||
| 800mm H x 500mm Double Glazed Heated Glass Medium Temperature |
1 Door | 2 Door | 3 Door | 4 Door | 5 Door | 6 Door | 7 Door | 8 Door |
|---|---|---|---|---|---|---|---|---|
| Store Conditions 25˚C & 60% RH | 174 | 299 | 423 | 519 | 641 | 765 | 845 | 986 |
| Store Conditions 30˚C & 70% RH | 193 | 336 | 479 | 593 | 734 | 877 | 975 | 1134 |
| Store Conditions 35˚C & 70% RH | 206 | 364 | 519 | 647 | 801 | 958 | 1069 | 1242 |
| Store Conditions 40˚C & 70% RH | 223 | 397 | 570 | 715 | 886 | 1059 | 1188 | 1377 |
Standard Series Low Temperature (Heated Glass) |
||||||||
| 800mm H x 500mm Double Glazed Heated Glass Medium Temperature |
1 Door | 2 Door | 3 Door | 4 Door | 5 Door | 6 Door | 7 Door | 8 Door |
|---|---|---|---|---|---|---|---|---|
| Store Conditions 25˚C & 60% RH | 276 | 498 | 721 | 943 | 1166 | 1388 | 1610 | 1832 |
| Store Conditions 30˚C & 70% RH | 304 | 535 | 768 | 1000 | 1232 | 1464 | 1695 | 1927 |
| Store Conditions 35˚C & 70% RH | 234 | 577 | 830 | 1083 | 1336 | 1589 | 1841 | 2094 |
| Store Conditions 40˚C & 70% RH | 349 | 627 | 906 | 1183 | 1462 | 1739 | 2017 | 2295 |
Home / Product Guide / About Us / Downloads / Technical Data / Contact Us